Photon Trap

At less than 10 % of cost, the patent-pending Photon Trap can facilitate realistic simulation of CW High Energy Lasers (HEL) at a portable/deployable platform for:
  • laser power calibration
  • optics damage threshold measurement
  • beam propagation characterization for Test and Evaluation (T&E) of High Energy Lasers

Photon Trap Model: PT-500kW

Prototype Photon Trap PT-500kW specification
Maximum intracavity laser power: 500 kW
Pumping diode power: <1 kW

PT-500kW Demonstration

The Radiation Pressure Meter measurement of the PT-500kW system as a function of the  intracavity laser power that was measured optically by monitoring the leakage laser power through the end mirror.



Demonstration of Dielectric Mirror Damage Threshold Measurement with PT-500kW

A damaged high power dielectric mirror during the CW laser damage threshold measurement:

  • Mirror reflectance  >0.999.
  • Mirror diameter: 2.5 cm
  • Intracavity laser beam power at the damage threshold:  260 kW
  • Intracavity laser beam diameter: 0.6 cm
  • Measured CW damage threshold: 920 ± 80 kW/cm2.